Skip to content
  • QUOTE
  • 888.653.333
  • info@safti.com
  • Products
    • Fire Protective Glass Tested to NFPA 252/257, UL 9/10C, ULC S104/S106; Blocks smoke and flames.
    • SuperLite® I
    • SuperClear® 45-HS
    • SuperClear® 45-HS-LI
    • SuperLite® I-XL
    • SuperLite® I-XL IGU
    • SuperLite® X-45/60/90
    • SuperLite® II-XL 45
    • Ceramics
    • Fire Resistive Glass Tested to ASTM E119 / UL 263 / ULC S101; Blocks smoke, flames and radiant heat.
    • SuperLite® II-XL 60
    • SuperLite® II-XL 90
    • SuperLite® II-XL 120
    • SuperLite® II-XLB 60
    • SuperLite® II-XLB 120
    • SuperLite® II-XLM 60
    • SuperLite® II-XLM 120
    • SuperSecure® II-XLS 45-120
    • Fire Rated Walls 60-120 minute fire resistive glass and frame assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® Architectural Series Fire Resistive
    • GPX® Curtain Wall
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Blast System
    • GPX® EZ Frame
    • Fire Rated Doors Full vision 20-45 minute fire protective doors and 60-90 minute temperature rise doors tested to NFPA 252 / UL 10C / ULC S104.
    • GPX® Architectural Series Fire Protective
    • GPX® Architectural Series Fire Resistive
    • GPX® Builders Series Fire Protective
    • GPX® Builders Series Temperature Rise
    • GPX® Hurricane
    • GPX® Ballistic
    • GPX® Vision Kit
    • Fire Rated Openings 20-45 minute fire protective glass and framing assemblies tested to NFPA 257 / UL 9 / ULC S106.
    • GPX® Architectural Series Fire Protective
    • GPX® Builders Series Fire Protective
    • GPX® EZ Frame
    • Fire Rated Floors 60-120 minute fire resistive glass floor assemblies tested to ASTM E119 / UL 263 / ULC S101.
    • GPX® FireFloor
    • Fire Rated Fences 20-60 minute fire rated glass fence for WUI areas or designated fire zones.
    • SAFTI FENCE
  • Literature
  • Specs
  • Details
  • Learn
    About Us
    Videos
    Case Studies
    Articles
    Blogs
    Continuing Education
    Literature
    BIM Library
    Industry Links
    Press Releases
    Testimonials
    Technical Bulletins
    Newsletters
    Product Selector
  • Gallery
  • Reps
  • Contact
  • Products
    • Fire Protective Glass
    • Fire Resistive Glass
    • Fire Rated Walls
    • Fire Rated Doors
    • Fire Rated Openings
    • Fire Rated Floors
    • Fire Rated Fences
  • Literature
  • Specs
  • Details
  • Learn
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Literature
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Reps
  • Contact
Menu
  • Products
    • Fire Protective Glass
    • Fire Resistive Glass
    • Fire Rated Walls
    • Fire Rated Doors
    • Fire Rated Openings
    • Fire Rated Floors
    • Fire Rated Fences
  • Literature
  • Specs
  • Details
  • Learn
    • About Us
    • Product Selector
    • Articles
    • Blogs
    • BIM Library
    • Case Studies
    • Newsletters
    • Press Releases
    • Continuing Education
    • Literature
    • Technical Bulletins
    • Testimonials
    • Industry Links
    • Videos
  • Gallery
  • Reps
  • Contact
Articles
Code Education
A History of Codes on 60 minute fire rated glass
Code Education

A History of Codes on 60 minute fire rated glass

ByDiana S
| October 7, 2014

How 60-Minute Code For Fire Rated Glass Changed Over Time. Read more.

A history of codes on 60 minute fire rated glass starts with the UBC and UL test standards. Over time, codes have been changed to require fire rated glass and framing that protects people and property from radiant heat, smoke and impact.

The excerpts below shows some historic references to codes addressing 60 minute fire rated glass applications.

1. UBC

– ICBO code Interpretations, Buildinq Standards, January 1991, attached, and updated November 2, 2000 interpretation referencing UBC 1997, quoted below.

The 1991 interpretation states cleady that 60-minute glazing must be rated as a fire resistive assembly:

UBC section 4306 (g)
“Section 43.301 of Uniform Building Code Standard No.43-4 limits the rating of light transmitting (or window) assemblies to 45 minutes.
For a window to be rated as a separate one-hour fire resistive assembly it would have to be tested as a wall assembly in accordance with UBC standard No.43-1, which would include the requirements for heat transmission. It would be extremely difficult for transparent glazing to comply with these heat transmission requirements, although some systems have been tested to this standard.”

(References UBC 1991; UBC Chapter 43 has been renumber as Chapter 7, and UBC Standards 43-1 and 43-4 have been renumbered as 7-1 and 7-4).

ICBO reconfirmed that interpretation in November 2000, in the following response by Staff Engineer, Mr. Bob Ayers, to the question:

Q: For a window to be rated for 60 minutes, should it be tested in accordance with UBC Standard 7-1 which is the Fire Test of Building Construction and Materials?

A: Yes. UBC Standard 7-4 specifies the requirements for the fire tests of window assemblies which are intended to evaluate the ability of a window or other light-transmitting assembly to remain in place during a predetermined test exposure of 45 minute durations. For a window to be rated for a greater test exposure time period, such as one hour, it would have to be tested as a wall assembly (or part of one) in accordance with UBC Standard 7-1 which would include the requirements for heat transmission and hose stream.

2. IBC – The IBC doesn’t specify any window, sidelight or transom applications over 45-minutes. Section 714.3 limits glazing in opening protectives tested to NFPA 257 to 45-minutes, and references NFPA 80, which does not recognize windows rated over 45-minutes per section 13-2.2. NFPA 80 makes it very clear in section 2-3.2.2, that glazing in sidelights and transoms is permitted in frames rated 45-minutes or less.

3. UL correspondence with TGP dated 2/1/89, acknowledging confusion over rating, clarifying testing went up to 60-minutes, but classified only for use in doors up to 1-1/2 hour, and frames rated up to 3/4, hour. (Attached).

The letter states:

As you advised me; there seems to be some confusion about your glazing material by some of the end users. As I confirmed: although your material was subjected to the fire exposure test longer than prescribed in the Test Standards UL 9 and UL 10B… their Classification is only for use in doors up to 1-1/2 hour, and frames rated up to 3/4, hour. Although your glazing was tested in a door assembly exposed to 3 hour of fire exposure and the frame was exposed to 1 hour fire exposure; the use of the material is limited by various code restrictions.

An additional point of confusion seems to revolve around your material’s ability to withstand fire exposure up to 1 hour. Even though it can withstand the fire exposure, it should not be considered interchangeable with various rated walls …. The testing and rating of walls is substantially different than the testing an rating of doors and frames. Each item is designed to have different installations, usages, and limitations.

4. Degenkolb, John D. “Gus”, former NFPA 80 Technical Committee Chairman, May 7, 1993 correspondence to UL criticizing rating of ceramic FireLite for 60-minutes without regard to radiant heat protection.

A problem involving the UL listing of fire- rated glass has been brought to my attention as Chairman of NFPA 80 …. It seems that UL is listing a glass-probably a ceramic material- as having a 60-minute listing by UL. The problem is, no building code with which I am familiar, has a requirement for l-hour glass but rather for 45-minutes based on the capability of wired glass…

Apparently a glass (other than Contraflam [SuperLite II]) has been tested successfully by UL for 60-minutes. As you are fully aware, neither the door or window test standard addresses temperature rise or radiant heat over the fire duration period. Enforcement officials and architects are being advised that, with 1-hour glass available for installation in a 1-hour wall, why settle for 3/4 -hour glass? Further, where Uniform Building Code limits the amount of glazing in a wall to 25% of the area involved, why not accept 40-50-or 60 percent since it is 1-hour glass. There are obvious answers as to why not but all building and fire officials are not that knowledgeable…

To me, it borders on the ridiculous to require that a 1-hour corridor wall be limited to a temperature rise of 250 degrees F above the ambient and then permit 25% of the wall area to have glazing with no imitation on the amount of heat coming through it. Some years ago, I conducted tests to determine what temperature the heat transmitted through a stairway door would cause the use of a unit to of exit width (22 inches) to be lost. It was determined that when there was a temperature rise of 450 degrees F above ambient, that unit of exit width adjacent the door could no longer be used. On that basis, plus the danger of transmitted heat igniting the materials on the other side of the wall, it seems to me that allowing an additional 15-minutes of heat transference is improper.

I think that UL should re-examine its listing and add some additional wording on the label or some other method to avoid misuse of the product.

Share:
PrevNext ArticleNYC Building Bulletin 2015-17 and Fire Rated Exterior Openings
Previous ArticleThe Truth About 60 minute Fire Rated GlassNext
Back to Articles

Engineering. Design. Code.

Whether you’re looking for fire-rated walls, doors, openings, floors or a specialty service, we have the solution for you. With over 40 years of experience in testing, innovating, and providing technologically advanced fire-rated glass and framing products, we deliver unyielding performance and quality at a competitive price.

Let's Talk!

  • 888.653.3333
    (English)
  • 888.653.3333 ext. 652
    (Spanish)
  • info@safti.com
  • Representative Map
Address
Corporate
100 N Hill Dr, Ste12, Brisbane, CA 94005
Factory
220 S R Street, Merced, CA 95341
Contact
Phone
888.653.3333 - English
888.653.3333 ext. 652 - Spanish
Fax
888.653.4444
Email
info@safti.com

Sign up for our Newsletter!

Get notified of industry updates and new product alerts.

© 2023 SAFTI FIRST. All rights reserved.​
Disclaimer & Privacy Policy | Cookie Policy
Instagram Twitter Linkedin Facebook Youtube Vimeo
Suggested Pages
Case Studies
Videos Archive [INACTIVE]
Request a Quote
SuperClear® 45-HS-LI
Continuing Education
Request a Quote
Continuing Education
Videos
SuperClear® 45-HS-LI
Case Studies
This website uses cookies to ensure you get the best experience on our website.

This website uses cookies to ensure you get the best experience on our website.


This website uses cookies to improve user experience. A cookie file is stored in your web browser and allows the website to recognize you and make your next visit easier and the website more useful to you. By using our website, you consent to all cookies in accordance with our Cookies Policy. Learn more.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Manage options Manage services Manage vendors Read more about these purposes
View preferences
{title} {title} {title}