Hurricane Framing with Florida Code Approvals for doors, openings and walls
- 60 to 120 minute fire resistive, hurricane rated aluminum framing system with Florida Product Approval Numbers:
- Fixed Window/Wall: FL16382
- Single and Pair Doors: FL 16888
- Meets to the following standards:
- ASTM E-119/NFPA251/UL263 up to 2 hours with hose stream for Fire Resistance
- ASTM E283 for Air Infiltration Leakage
- ASTM E331/ASTM 547 for Water Penetration
- ASTM E330/TAS 202 for Uniform Static Air Pressure
- FBC 1626.2 (TAS 201 and 203) for Large Missile Impact and Cyclic Wind Loading
- AAMA 1302.5-76 and 1303.5-76 for Forced Entry (for doors)
- ASTM E1300 for Determining Load Resistance of Glass in Buildings
- Complies with High Velocity Hurricane Zone (HVHZ) testing requirements.
- Maximum design loads up to +/- 80 PSF.
- Glazing make-up is SuperLite II-XL insulated with 9/16″ DuPont Sentry Plus Laminated Glass
- Dow Corning 995 to be used as the perimeter sealant
- Enrolled in Architectural Testing Inc.’s Quality Assurance Program
- Offered in standard and custom finishes including high performance fluoropolymer finishes by PPG, clear anodized, bronze anodized, black anodized, Decoral®, ornamental metal, and more.